  • Study of starting and running procedure of an Auxiliary engine under different load condition.
  • Checks to be made while running of Auxiliary Engine
  • STUDY ABOUT AUXILIARY MACHINERIES INVOLVED IN AUXILIARY ENGINES OPERATION.
  • STUDY OF SMOKE TUBE BOILER STARTING AND OPERATION
  • STUDY OF WATER TUBE BOILER STARTING AND OPERATION
  • BOILER LAY OFF PROCEDURE
  • BOILER MOUNTINGS
  • BLOWTHROUGH OF GAUGE GLASS
  • BOILER SAFTETY VALVE
  • STEAM TURBINE OPERATION, PERFORMANCE AND MAINTENANCE
  • PERPARING, STARTING AND RUNNING OF MARINE PROPULSION ENGINE
  • REVERSIBLE MARINE PROPULSION ENGINE (TWO STROKE ENGINE)
  • PERFORMANCE AND RUNNING MAINTENANCE OF MARINE PROPULSION ENGINE
  • OVERHAULING OF GENERATOR
  • PERIODIC MAINTENANCE AND OVERHAULING OF ELECTRICAL SYSTEMS ONBOARD

Study of starting and running procedure of an Auxiliary engine under different load condition.

Procedure: Starting of Auxiliary Engine

Starting of an auxiliary engine from "stop" state is something which needs to be done with care, especially if the interval of starting is very long. The following is a checklist in which all the checks to be carried out before starting the engine. In fact these checks are generic for any four stroke engine starting process

  1. Check the sump oil level, governor oil level ,turbocharger oil level and fuel oil level in service tank
  2. Open the indicator cock
  3. Prime the lube oil to all parts by hand pump or by motor driven priming pump
  4. Ensure that all jacket cooler valves, lube oil cooler valves, air cooler valves should be in open position
  5. With use of the Turning bar turn the fly wheel and check for any resistance on the bottom end bearing and check any water / fuel coming out through indicator cocks
  6. While turning engine, check all visible lube oil points are lubricated
  7. Remove the turning bar from fly wheel and put in the place
  8. Drain the auxiliary air bottle
  9. Blow through engine (ie: by turning engine with air). In order to ensure that no water is inside combustion chamber if it is present it may cause water hammering
  10. Close the indicator cocks and pull lever from stop to start
  11. When the needle in RPM indicator deflects to some value of (0-25 rpm) put the lever in run condition
  12. The engine will run on fuel oil once the generator picks up the rated speed
  13. Put generator on load by closing air circuit breaker
  14. For checking the alternator fore and aft bearing lube oil level by opening oil plug in the alternator and the ring bearing while rotating splash lube oil from the sump can be seen
  15. In order to synchronize the incoming generator with running generator synchronscope method/dark lamp method is used.